CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Uchida, T.
Right arrow Articles by Yasuda, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Uchida, T.
Right arrow Articles by Yasuda, K.

Canadian Journal of Anesthesia, Vol 44, 674-676, Copyright © 1997 by Canadian Anesthesiologists' Society


ARTICLES

The McCoy levering laryngoscope in patients with limited neck extension

T Uchida, Y Hikawa, Y Saito and K Yasuda
Department of Anesthesia, Tokyo Metropolitan Hospital of Fuchu, Japan.

PURPOSE: The McCoy levering laryngoscope is a modified Macintosh laryngoscope, which has a hinged tip controlled by a lever on the handle. The purpose of this study was to investigate whether the tip elevation of this laryngoscope results in better laryngeal visualization than using the Macintosh laryngoscope when the patient's neck is fixed in the neutral position. METHODS: Fifty female patients (ASA physical status I-II) undergoing elective surgery during general anaesthesia were investigated. The patient's neck was manually fixed in the neutral position by an assistant, and laryngeal visualization was attempted first with a size #3 Macintosh laryngoscope (Macintosh trial), and then with a size #3 McCoy levering laryngoscope with blade tip elevation (McCoy trial), and tracheal intubation was attempted. Trials of laryngeal visualization were evaluated with the Cormack score. RESULTS: In the Macintosh trial, 36 of 50 (72%) patients were evaluated grade 3, and two grade 4. In most of the patients graded 2 and 3 in the Macintosh trial (70% of the grade 2 and 83% of the grade 3 cases), the laryngeal view was improved by using the McCoy levering laryngoscope. The Cormack grade in the McCoy trial was less than that in the Macintosh trial (P < 0.01). No complications were observed during the study. CONCLUSION: The McCoy levering laryngoscope improved laryngeal visualization in patients whose neck cannot be extended.


This article has been cited by other articles:


Home page
Br J AnaesthHome page
M. A. Malik, C. O'Donoghue, J. Carney, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Comparison of the Glidescope(R), the Pentax AWS(R), and the Truview EVO2(R) with the Macintosh laryngoscope in experienced anaesthetists: a manikin study
Br. J. Anaesth., January 1, 2009; 102(1): 128 - 134.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. A. Malik, C. H. Maharaj, B. H. Harte, and J. G. Laffey
Comparison of Macintosh, Truview EVO2(R), Glidescope(R), and Airwayscope(R) laryngoscope use in patients with cervical spine immobilization
Br. J. Anaesth., November 1, 2008; 101(5): 723 - 730.
[Abstract] [Full Text] [PDF]


Home page
TraumaHome page
S. Carley and C. Gwinnutt
Stepwise airway management in the trauma patient
Trauma, July 1, 2004; 6(3): 177 - 185.
[Abstract] [PDF]


Home page
Canadian J. AnesthesiaHome page
E. McCoy
The McCoy laryngoscope in infants and children/L'usage du laryngoscope McCoy chez les enfants
Can J Anesth, February 1, 2004; 51(2): 101 - 105.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
G. Iohom, R. Franklin, W. Casey, and B. Lyons
The McCoy straight blade does not improve laryngoscopy and intubation in normal infants: [La lame droite McCoy n'ameliore pas la laryngoscopie ni l'intubation chez des enfants normaux]
Can J Anesth, February 1, 2004; 51(2): 155 - 159.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. Andrew Ochroch and R. M. Levitan
A Videographic Analysis of Laryngeal Exposure Comparing the Articulating Laryngoscope and External Laryngeal Manipulation
Anesth. Analg., January 1, 2001; 92(1): 267 - 270.
[Abstract] [Full Text] [PDF]


Home page
Emerg. Med. J.Home page
S. Carley and J. Butler
Use of the McCoy laryngoscope in patients with suspected cervical spine fracture
Emerg. Med. J., September 1, 2000; 17 (5): 364 - 365.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the Canadian Anesthesiologists' Society.