CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wood, C.
Right arrow Articles by Sheppard, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wood, C.
Right arrow Articles by Sheppard, S.

Canadian Journal of Anesthesia, Vol 39, 682-686, Copyright © 1992 by Canadian Anesthesiologists' Society


ARTICLES

Exposure of operating room personnel to nitrous oxide during paediatric anaesthesia

C Wood, A Ewen, G Goresky and S Sheppard
Department of Anaesthesia, Alberta Children's Hospital, University of Calgary.

This study was undertaken to quantify the exposure of operating room staff to nitrous oxide during routine paediatric otolaryngeal surgery and to determine the influence of the method of induction of anaesthesia on this exposure. The nitrous oxide exposure of the anaesthetist, the surgeon and the circulating nurse were measured, using body-worn passive atmospheric samplers, during twelve routine paediatric otolaryngeal surgical lists. During six of the lists an inhalational technique, with nitrous oxide, oxygen and halothane, was used for the induction of anaesthesia. During the other six lists anaesthesia was induced using intravenous thiopentone. In all cases, anaesthesia was maintained using nitrous oxide, oxygen and halothane. Regardless of the induction technique used, the mean nitrous oxide exposures of the anaesthetist, the surgeon and the nurse all exceeded the maximum level of 25 ppm.hr-1 recommended by the United States National Institute for Occupational Safety and Health (NIOSH). The use of an intravenous technique for the induction of anaesthesia reduced the nitrous oxide exposure of the anaesthetist and the circulating nurse. This suggests that, although the use of an intravenous induction may reduce exposure to nitrous oxide, the NIOSH recommendations for maximum exposure of operating room personnel to nitrous oxide are currently unattainable in practice.


This article has been cited by other articles:


Home page
Br J AnaesthHome page