CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martineau, R. J.
Right arrow Articles by Hull, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martineau, R. J.
Right arrow Articles by Hull, K. A.

Canadian Journal of Anesthesia, Vol 37, 755-761, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

Alfentanil controls the haemodynamic response during rapid-sequence induction of anaesthesia

RJ Martineau, CP Tousignant, DR Miller and KA Hull
Department of Anaesthesia, Ottawa General Hospital, Ontario.

Laryngoscopy and tracheal intubation often cause hypertension and tachycardia, which may be exaggerated during rapid-sequence induction of anaesthesia. A placebo-controlled, double-blind study was conducted in 60 patients to determine dose-response and effects on myocardial performance of alfentanil when used to attenuate this cardiovascular response. Patients were divided into four groups to receive a pre-induction bolus from a coded syringe, which contained either normal saline (PLAC), alfentanil 30 micrograms.kg-1 (ALF 30), alfentanil 45 micrograms.kg-1 (ALF 45) or alfentanil 60 micrograms.kg-1 (ALF 60). Anaesthesia was induced in rapid sequence with thiopentone 4.0 mg.kg-1 and succinylcholine 1.5 mg.kg-1, and the trachea was intubated 60 sec later. Increases in heart rate (21 +/- 10 bpm), mean arterial pressure (28 +/- 13 mmHg), and systemic vascular resistance index (1420 +/- 780 dynes.sec-1.cm-5) were observed in response to intubation with PLAC but in none of the 3 ALF groups (P less than 0.05). However, heart rate and mean arterial pressure decreased significantly in both the ALF 45 and ALF 60 groups (P less than 0.05), whereas ALF 30 resulted in no change in these variables over time. Cardiac index, stroke volume index, and ejection fraction tended to decrease in all four groups, but none of these variables was different at corresponding time when comparing the ALF groups with PLAC.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.