CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Russell, G. B.
Right arrow Articles by Strout, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Russell, G. B.
Right arrow Articles by Strout, J. C.

Canadian Journal of Anesthesia, Vol 37, 560-566, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

Stability of arterial to end-tidal carbon dioxide gradients during postoperative cardiorespiratory support

GB Russell, JM Graybeal and JC Strout
Department of Anesthesia, Pennsylvania State University, College of Medicine, Milton S. Hershey Medical Center, Hershey 17033.

The changes in the arterial to end-tidal carbon dioxide gradient. P(a-ET)CO2, were studied in postoperative cardiac surgery patients from the time of admission to the intensive care unit, during changing cardiorespiratory support, up to the time of tracheal extubation. Individual factors evaluated for their effects on P(a-ET)CO2 included rate of mechanical ventilation, infusion of vasoactive agents (nitroglycerin, nitroprusside, dopamine, dobutamine, and metariminol), and associated changes in haemodynamic pathophysiology (cardiac index, pulmonary artery pressure, pulmonary vascular resistance index, systemic vascular resistance index, and pulmonary capillary wedge pressure). After approval by the Clinical Investigation Committee, 59 patients, age 63 +/- 9 (41 to 75) yr, were studied and 382 individual gradient determinations made. Mean P(a-ET)CO2 was 5.47 +/- 5.21 mmHg, with the mean PaCO2, 36.51 +/- 5.89 mmHg and mean ETCO2, 31.04 +/- 6.44 mmHg. For the population as a whole, the correlation between PaCO2 and ETCO2 determined by regression analysis was maintained (R = 0.644, P less than 0.001). Comparison of the individual and population correlation coefficients by Student's t test showed no significant difference, but a normal population distribution of the gradients (P less than 0.05). None of the variables assessed could be determined to influence P(a-ET)CO2 significantly. For many of the individual patients, however, the relationship between PaCO2 and ETCO2 did not maintain a significant correlation throughout the study period. In the postoperative cardiac surgery patient population P(a-ET)CO2 follows a normal distribution and PaCO2 and ETCO2 maintain a statistically significant correlation. However, when evaluating individual patients, this relationship has wide variability.


This article has been cited by other articles:


Home page
Emerg. Med. J.Home page
C Yosefy, E Hay, Y Nasri, E Magen, and L Reisin
End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting
Emerg. Med. J., September 1, 2004; 21(5): 557 - 559.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
P. Seguin, J. P. Bleichner, B. Branger, Y. M. Guillou, A. Feuillu, and Y. Malledant
La pression tele expiratoire en CO2 n'est pas un parametre pertinent de surveillance d'un traumatisme cranien grave
Can J Anesth, April 1, 2001; 48(4): 396 - 400.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. Grenier, E. Verchere, A. Mesli, M. Dubreuil, D. Siao, M. Vandendriessche, J. Cales, and P. Maurette
Capnography Monitoring During Neurosurgery: Reliability in Relation to Various Intraoperative Positions
Anesth. Analg., January 1, 1999; 88(1): 43 - 48.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
J. Aittomaki
Monitoring of CO2 exchange during cardiopulmonary bypass: the effect of oxygenator design on the applicability of capnometry
Perfusion, July 1, 1993; 8(4): 337 - 344.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.