CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McEvedy, B. A.
Right arrow Articles by Lerman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McEvedy, B. A.
Right arrow Articles by Lerman, J.

Canadian Journal of Anesthesia, Vol 37, 322-326, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

End-tidal carbon dioxide measurements in critically ill neonates: a comparison of side-stream and mainstream capnometers

BA McEvedy, ME McLeod, H Kirpalani, GA Volgyesi and J Lerman
Department of Anaesthesia, Hospital for Sick Children, University of Toronto, Ontario.

To determine whether end-tidal PCO2 (PETCO2) measurements obtained with two infrared capnometers accurately approximates the arterial PCO2 (PaCO2) in critically ill neonates, simultaneous measurements of PETCO2 were obtained from the distal and proximal ends of the tracheal tube with a sidestream capnometer (Puritan Bennett/Datex--BP/D) and from the proximal end with a mainstream capnometer (Hewlett-Packard-HP) in 20 intubated neonates. Distal sidestream PETCO2 and mainstream PETCO2 correlated with the PaCO2 (r2 = 0.66 and 0.61, respectively) within the range of 26-57 mmHg PaCO2. However, proximal PETCO2 with the sidestream capnometer correlated very poorly (r2 = 0.09) with PaCO2. The slope of the least square regression line for the distal sidestream capnometer, 0.67, was significantly less than that for the mainstream capnometer, 0.78 but both were significantly greater than that for the proximal sidestream capnometer, 0.39 (P less than 0.05). The slope of the regression for the proximal sidestream capnometer did not differ significantly from horizontal. Insertion of the mainstream sensor for the HP capnometer significantly increased the transcutaneous CO2 when compared with preinsertion values. We conclude that both distal sidestream and mainstream capnometry provide accurate estimates of the PaCO2 in critically ill neonates.


This article has been cited by other articles:


Home page
PediatricsHome page
A. Kugelman, D. Zeiger-Aginsky, D. Bader, I. Shoris, and A. Riskin
A Novel Method of Distal End-Tidal CO2 Capnography in Intubated Infants: Comparison With Arterial CO2 and With Proximal Mainstream End-Tidal CO2
Pediatrics, December 1, 2008; 122(6): e1219 - e1224.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
H. J. Rozycki, G. D. Sysyn, M. K. Marshall, R. Malloy, and T. E. Wiswell
Mainstream End-tidal Carbon Dioxide Monitoring in the Neonatal Intensive Care Unit
Pediatrics, April 1, 1998; 101(4): 648 - 653.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.