CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hillier, S. C.
Right arrow Articles by Lerman, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hillier, S. C.
Right arrow Articles by Lerman, J.

Canadian Journal of Anesthesia, Vol 37, 318-321, Copyright © 1990 by Canadian Anesthesiologists' Society


ARTICLES

Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator

SC Hillier, JM Badgwell, ME McLeod, RE Creighton and J Lerman
Department of Anaesthesia, Hospital for Sick Children, University of Toronto, Ontario, Canada.

To determine the accuracy of end-tidal PCO2 (PETCO2) measurements analyzed with a sidestream capnometer in infants and children whose lungs were ventilated with a Sechrist infant ventilator and an Ayre's t-piece, we compared PETCO2 measurements obtained from the proximal (PETCO2-p) and distal (PETCO2-d) ends of the tracheal tube to arterial PCO2 (PaCO2) in 37 healthy infants and children between 1.3 and 24.5 kg. Both PETCO2-p and PETCO2-d accurately approximated PaCO2, however, the mean (+/- SD) arterial to end-tidal PCO2 difference (delta(a-ET)PCO2) was significantly greater with proximal (1.27 +/- 1.54 mmHg) than with distal sampling (0.64 +/- 1.64 mmHg) (P less than 0.01). In the subgroup of patients who weighted less than 12 kg, the delta(a-ET)PCO2 using proximal gas sampling (1.94 +/- 1.29 mmHg) was also significantly greater than it was using distal sampling (0.74 +/- 1.31 mmHg) (P less than 0.001). We conclude that although statistically different, both proximal and distal estimates of PETCO2 provide acceptable estimates of PaCO2 in healthy infants and children who are ventilated with a Sechrist infant ventilator and an Ayre's t-piece system.


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
D G Tingay, M J Stewart, and C J Morley
Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2005; 90(6): F523 - F526.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. Oshibuchi, S. Cho, T. Hara, S. Tomiyasu, T. Makita, and K. Sumikawa
A Comparative Evaluation of Transcutaneous and End-Tidal Measurements of CO2 in Thoracic Anesthesia
Anesth. Analg., September 1, 2003; 97(3): 776 - 779.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J. D. Tobias, W. R. Wilson Jr., and D. J. Meyer
Transcutaneous Monitoring of Carbon Dioxide Tension After Cardiothoracic Surgery in Infants and Children
Anesth. Analg., March 1, 1999; 88(3): 531 - 531.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
H. J. Rozycki, G. D. Sysyn, M. K. Marshall, R. Malloy, and T. E. Wiswell
Mainstream End-tidal Carbon Dioxide Monitoring in the Neonatal Intensive Care Unit
Pediatrics, April 1, 1998; 101(4): 648 - 653.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1990 by the Canadian Anesthesiologists' Society.