CJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text (PDF)
Right arrow Submit a scholarly reply
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by BEREZOWSKYJ, J. L.
Right arrow Articles by JENKINS, L. C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by BEREZOWSKYJ, J. L.
Right arrow Articles by JENKINS, L. C.

Canadian Journal of Anesthesia, Vol 23, 1-8, Copyright © 1976 by Canadian Anesthesiologists' Society

A Study of Anaesthesia Depth by Power Spectral Analysis of the Electroencephalogram (EEG)

J. L. BEREZOWSKYJ 1, J. A. McEWEN 2, G. B. ANDERSON 2, and L. C. JENKINS 1

1 Department of Anaesthesiology, University of British Columbia, Vancouver, B.C.
2 Department of Electrical Engineering, University of British Columbia, Vancouver, B.C.

The feasibility of using computer-based EEG spectral analysis to monitor the level of anaesthesia during nitrous oxide-alphaprodine anaesthesia has been established by this study. At present, this system is capable of estimating the level of anaesthesia correctly from 55 per cent to 80 per cent of the time. There are several possible clinical applications of such a monitoring system during anaesthesia.

It provides a continuous estimation of the depth of anaesthesia, without requiring any special EEG training on the part of the anaesthetist. This system can also be of particular benefit during anaesthesia for critically ill patients, or in specific cases, as in neurosurgery and caesarian section when there may be periods of time when the gross clinical evaluation of depth of anaesthesia may not be precise or reliable and yet it is imperative not to deepen the anaesthesia unnecessarily. In such instances it appears that a monitoring system such as we have developed could provide valuable indication of the depth of anaesthesia. Other potential applications might be in the training of students in the clinical assessment of patients during anaesthesia and in the study of new anaesthetic agents.